中国民间中医医药研究开发协会国际针灸合作委员会
办公地点现在已经搬迁至西城区西直门南小街国英园一号楼824室,
同时为方便大家联系,固定电话已经变更
新号码010—58562339。特此通知。
地址:北京西城区西直门南小街国英园一号楼824室
邮编:100035
电话:010-58562339
传真:010-58562339
邮箱:cngjzj@163.com
网站(点击网址直接链接↓):http://www.cngjzj.com/
博客(点击网址直接链接↓):http://blog.sina.com.cn/cngjzj
交通路线图 (点击观看大图)
从首都机场乘坐机场专线,在东直门站下车换乘地铁2号线开往西直门方向,在西直门站 C 口出站:
1、沿西直门内大街向东直行100米,右拐到西直门南小街,向南步行到丁字路口即到国英园1号楼楼下。
2、向南直行50米,绕过 国二招宾馆 沿着中大安胡同向东到西直门南小街,向南步行到丁字路口即到国英园1号楼楼下。
从首都机场内乘坐机场直达西单的大巴,在西单站下车,乘坐出租车到西直门南小街国英园1号楼。
公交官园站:107路,运通106路
公交西直门南:387路,44路,800内环,816路,820内环,845路
地铁车公庄:地铁二号线
地铁西直门:地铁二号线
公交车公庄东:107路,118路,701路
公交车公庄北:209路,375路,392路
您现在的位置是:
首页 >>
Technology promotion技术推广 >>
Technology promotion技术推广
2015年07月10日
Helpful hints: Mr Ma Lichang 2 -- 4 per month in Beijing, in the Chinese folk medicine research and development of traditional Chinese medicine association international acupuncture cooperation committee on-site technical communication transmission services, interested parties please call to make an appointment in advance to sign up, at nine o 'clock every day - 18 points, phone calls: 010-58562339
Mr Ma Lichang introduction: http://www.cngjzj.com/content.asp?Id=40635
Ma Lichang embedded wire therapy basis collection (29) serial
Embedded wire technology practice
The 2015-6-11 05:48
Minimally invasive embedded wire technology is the application of disposable minimally invasive embedded wire needle will PGA biological absorbable materials such as certain parts or meridians preparetions into the human body, through the role of the long lines of local or acupuncture point an acupuncture treatment technique for disease treatment.
1 the instrument
Minimally invasive needle buried lines should use disposable needle buried line, material should use biological absorbable line style such as the PGA material, treatment should be prepared before the iodine volts or 2% iodine volts, alcohol, glue stick, scissors, tweezers, surgical instruments plate and other products.
2 operation requirements
2.1
Environmental requirements
Embedded wire chamber shall have the independent room, area of not less than 20 m2, it should be roughly divided into three areas: the general work area, clean, sterile, indoor should be disinfected regularly. Easy to clean, the sterilization, to maintain a low dust, home invasion replacement slippers or wear shoe covers, must wear masks and isolation cap.
2.2 disinfection requirements
In embedded wire must wash your hands before operation, the operation on disinfected with 2% iodine volts, skin with the needle point as the center, outward from the center of rotation with spiral movement inunction 2 times, should be more than 2 cm in diameter, after being tincture of iodine volatility, using 70% ethanol iodine, range than the tincture of iodine disinfection area, stay dry rear can bury a line (also available iodine volts direct buried after disinfection line).
2.3 position requirements
Minimally invasive embedded wire commonly used general for supine position and prone position, also can be used in a lateral position according to need, such as seat position for embedded wire treatment.
3 steps
3.1 patients with stomach or supine, exposed the embedded wire required parts, with 75% alcohol or iodine disinfection local skin.
3.2 prepare needle and thread. With your right thumb and forefinger and middle finger knead a needle handle, the index finger presses the spring a few times repeatedly, to check the needle with needle core status.
3.3 in the spring under the natural state, with tweezers and take a biological absorbable thread, in a front-end buried line beard needle tube, push the line body gently into the needle with forceps. Pay attention to the line must be completely in the needle body, do not on the outside of the tip.
3.4 according to the needle into different parts, the left hand thumb and index finger tight or filed into the needle, skin right hand thumb and forefinger and middle finger knead a needle handle, quickly with a wrist needle into the skin, and gradually reach the appropriate depth.
3.5 at the bottom of the right index finger to gently push the needle core, push the line body completely into the acupuncture point, at the same time, the thumb and middle finger knead a needle handle gently out of the needle body, repeated pressure needle core is 2-3 times, make sure the line body completely.
3.6 will tip out of the skin, at the same time with dry cotton swab oppression pinhole immediately for a moment, and apply the medical infusion glue stick.
3.7 after the operation, let the victim rest slightly 5 ~ 10 minutes, you can leave, informed patient after wire embedded matters needing attention.
4 points for attention
Detailed introduction to the patients before 4.1 embedded wire embedded wire operation and matters needing attention, to eliminate the patient's psychological tension and suspicion.
4.2 line of body to prevent damage blood vessels and nerves, when implanted at the same time to avoid inflammation, purulent infection, induration, flecked and skin disease.
4.3 when push pin core resistance is strong, should be repeated with your index finger snap up and down several times, then gently roll out line body.
4.4 if encounter patients nervous, muscles taut, the needle is difficult, should be tapping the acupoints, relax when pulled out to patients.
4.5 due to the improper operation line body failed to fully implanted subcutaneous, use tweezers immediately take round body, embedded wire again.
4.6 the postoperative charged 24 hours can't bath, protect wound from infection.
4.7 the postoperative subcutaneous haematomas blood stasis, mild fever, induration, slight pain, such as a normal phenomenon of reaction, can eliminate 1 ~ 2 weeks.
5 indications
Minimally invasive embedded wire acupuncture technology application range is wide, safe in operation and suitable for clinical acupuncture and moxibustion can be most painful disease and treatment of common medical problems.
6 contraindications
6.1 fever or infection, the body of various severity disease, allergic constitution, liver and kidney function is not complete, and patients with infectious diseases.
6.2 pregnant women, nursing mothers, women's menstrual period.
6.3 patients with hemophilia, thrombocytopenia, and bleeding tendency can't use this surgery.
6.4 patients with vigorous exercise, drink, supersaturated hunger cannot be buried immediately.