Contact Us

 

 

  

Address: Beijing's xizhimen south street, xicheng district

 

The British garden 1 floor. Room 824

 

Zip code: 100035

 

Telephone: 010-58562339

 

Fax: 010-58562339

 

Email address: cngjzj@163.com

 

Web site (click on the url link directly left) :

 

http://www.cngjzj.com/

 

Blog (click on the url link directly left) :

http://blog.sina.com.Cn/CNGJZJ

 

To xizhimen south street, xicheng district building to the British garden route

L airport line 1

Take the airport shuttle from the airport, the dongzhimen station transfer to metro line 2 to xizhimen direction and get off at xizhimen station, from C outbound, go straight to the east 100 meters on the right side to xizhimen south street, north to walk to the t-junction namely to the British garden 1 floor downstairs.

L airport line 2

From the capital airport take airport bus to xidan, get off at no.22, take a taxi to xizhimen south street English garden 1 floor.

L bus subway near:

106 bus GuanYuan: 107 road, express way

Bus: xizhimen south road 387, 44 road, inner ring 800, 816 road, inner ring 820, 845 road

Che zhuang: subway line two

Xizhimen subway: metro line 2

Buses and attempts: 107 road, 118 road, 701 road

Buses and north zhuang: 209 road, 375 road, 392 road

 

Blood pressure self-test family how to quasi

2012年08月20日

复制链接 打印 大 中 小

<

 

 

 

Blood pressure self-test family how to quasi

 

 

Shanghai hypertension institute director WangJiGuang

 

 

Sources: health

 

 

 

        How to correctly monitoring blood pressure? Every day the best measure how many times? What time should be measured? Measuring blood pressure should keep what position? What should be paid attention to details? In the recently held a family blood pressure monitoring China experts consensus promotion conference, experts gives the clear answer.

 

        Sphygmomanometer choice: do not recommend the use of any form of mercury sphygmomanometer. Mercury sphygmomanometer need to use stethoscope sure systolic blood pressure and diastolic blood pressure, requires a special training to distinguish clearly. And mercury is a kind of for the human body has serious harm of heavy metal, once into the environment will always be in environment and between organisms cycle. We preferred recommended electronic sphygmomanometer, and had better be automatic upper arm type electronic sphygmomanometer. Because of its accuracy and repeatability is good, clinical research evidence more, and method of measurement is easy to grasp. WanShi electronic sphygmomanometer measurement need not exposed upper arm, to take off clothes don't convenient person or liquidity large crowd easy to use. Note that, the choose and buy electronic sphygmomanometer should pay attention to see if it has clinical verification certificate, this is the guarantee of the accuracy. In addition, sphygmomanometer in use period should be regularly calibration, every year at least 1 time, can be in the place of purchase or go to a doctor place for help for calibration.

 

        Measuring the preparing work before: in the measurement of blood pressure in quiet environment is required before sitting position rest 5 ~ 10 minutes, after the movement must be rest for 30 minutes, make body and mind is loosened, breathing, heart rate stable, and then began to measurement. At the same time should avoid measurement emotional tension, measure blood pressure before no smoking, drinking alcohol, shower.

 

        Position, posture and operation: the gauger take prostrate or sitting position. Choose sitting position measurement, gauger should be sitting in a chair chair, two legs be born to relax. When measuring the elbow joint and heart at the same level, upper arm unbend slightly abduction. Sleeve with balloon close to the skin, lower edge distance of the elbow transverse striation 2 ~ 3 centimeters, don't too tight or too loose.

 

        Measuring time: it is recommended that daily early (wake up), late (before you go to bed each measurement 2 ~ 3 times, interval for 1 minute. To begin or treatment should be in early before a continuous measurement 5 ~ 7 days, blood pressure control is good, at least 1 day a week measurement. Home blood pressure was 135/85 MMHG may be diagnosed with high blood pressure, < 130/80 MMHG for normal blood pressure. Usually, the morning blood pressure is higher, at night, have lower blood pressure. Should be in the morning before breakfast and measure blood pressure before taking the medicine. Night Suggestions at supper, medication, bath at least 30 minutes later, in bedtime blood pressure measurement.

 

        Need to pay attention to is that a person's blood pressure is always in constant change, emotions and position, noise, the influence of such factors as temperature. If measuring blood pressure condition is not stable, even if continuous measurement, blood pressure can also have a large fluctuation, and even up to 10 mm mercury column above. Thus it can be seen, not only by occasionally two blood pressure measurement difference situation to judge the stability of the sphygmomanometer or accuracy.